Electrochemical-type Online COD Analyzer, HACA-2000, quantifies COD from the amount of current that is generated from oxidizing organic matter by using voltammetry method. The core technology, Composite Material Electrode, can be generated with simple polishing. Because it doesn’t require strong acid or high temperature conditions, it is easy to operate and manage as well as economical. It has less clogging due to the use of large tubes, and it can automatically check the supply of sample and reagent.
Characteristics
HACA-2000
-
Low maintenance cost : Renewable electrode
-
Improved measurement accuracy
-
Short measurement time
-
Status condition display
Principle
- When the optimum operating voltage is given to the composite material electrode that includes a catalyst, the catalyst that is distributed within the electrode induces oxidation reaction. Here, the measured amount of current and charge is proportional to the concentration of organic matter, it measures by converting this into COD value.
Specification
-
-
- Measurement item
-
Chemical Oxygen Demand (COD)
-
- Measurement method
-
Electrochemical decomposition
-
- Measurement principle
-
Conversion to COD concentration from electrical signal generated during electrochemical oxidation
-
- Measurement range
-
0~200mg/L (Adjustable)
-
- Measurement interval
-
20 minutes (Adjustable)
-
- Accuracy
-
±2% F.S.
-
- Reproducibility
-
±2% F.S.
-
- Linearity
-
±3% F.S.
-
- Zero/Span drift
-
±2% F.S.
-
- Oxidation potential
-
2.85V or more
-
- Operation system
-
Windows 7 (CPU process) or more
-
-
-
- Output
-
TCP/IP, DC 4~20mA, RS-232C
-
- Status display
-
Normal operation, on calibration, error
-
- Display
-
Color LCD 10.4″ (Touch screen)
-
- Power
-
AC 220V, 50/60Hz
-
- Power consumption
-
Average 85W
-
- Voltage regulation
-
3% or less
-
- Data storage capacity
-
HDD 100G or more
-
- Data output
-
USB terminal
-
- Enclosure / Size
-
Steel, IP55 / 600(W) × 662(D) × 1700(H) mm
-
- Operating humidity
-
RH 95% or less
-
Application
Application Field
-
Surface water monitoring
- River, lake, river water quality
- Waterworks facilities (intake station and Water plant, etc.)
-
Water quality TMS
- Sewage treatment plant, Wastewater treatment plant
- Wastewater discharging facility, Rural sewage treatment facility, etc.
-
Process control, etc.
- STP process management,
- IWWTP process management, etc.
Installation Pictures
-