Manganese-type Online COD Analyzer, HACA-3000, is measuring equipment that automated the Standard Water Pollutant Testing Method. HACA-3000 has a simple configuration that has adopted the 5-port control valve to enable inflow of fixed quantity of sample and reagent for the purpose of accurate measurement. It has less clogging due to the use of large tubes, and it can automatically check the supply of sample and reagent. It has extensive applications in the management of drinking water quality, wastewater, industrial effluent, groundwater, rivers, and ecosystem samples.
Characteristics
HACA-3000
-
Simple structure:5-port control valve
-
Compliance with the Standard Water Pollutant Testing Method
-
Easy and convenient operation
-
Status condition display
-
Functions that separately discharges
hazardous waste liquid and general liquid (Option)
Principle
- HACA-3000 measures COD by using the potassium permanganate method. Potassium permanganate method is a method that displays the pollution level of a sample by heating KMnO4 and letting it react to the heat for a certain time, and then converting the amount of oxygen that responds to the amount of KMnO4 that is consumed when the organic matter in the sample is oxidized.
Specification
-
-
- Measurement item
-
Chemical Oxygen Demand (COD)
-
- Measurement method
-
Decomposition method by chemical oxidants (Acidic condition, Potassium permanganate)
-
- Measurement range
-
0~200mg/L (Adjustable)
-
- Measurement interval
-
60 minutes (Adjustable)
-
- Accuracy
-
±2% F.S.
-
- Reproducibility
-
±2% F.S.
-
- Linearity
-
±4% F.S.
-
- Zero/Span drift
-
±2% F.S.
-
- Reactor heating
-
Oil heating by heater coil
-
- Sample/Reagent measuring method
-
Photo sensor pulse control
-
- Sample/Reagent distribution method
-
5-port distribution control method (Fixed quantity injection with multi-channel valve system)
-
-
-
- Operation system
-
Windows 7 (CPU process) or more
-
- Output
-
TCP/IP, DC 4~20mA, RS-232C
-
- Status display
-
Normal operation, on calibration, error
-
- Display
-
Color LCD 10.4″ (Touch screen)
-
- Power
-
AC 220V, 50/60Hz
-
- Power consumption
-
Average 150W (Maximum 450W)
-
- Voltage regulation
-
3% or less
-
- Data storage capacity
-
HDD 100G or more
-
- Data output
-
USB terminal
-
- Enclosure / Size
-
Steelã€IP55 / 600(W) â…¹ 662(D) â…¹ 1700(H) mm
-
- Operating humidity
-
RH 95% or less
-
Application
Application Field
-
Surface water monitoring
- River, lake, river water quality
- Waterworks facilities (intake station and Water plant, etc.)
-
Water quality TMS
- Sewage treatment plant, Wastewater treatment plant
- Wastewater discharging facility, Rural sewage treatment facility, etc.
-
Process control, etc.
- STP process management,
- IWWTP process management, etc.